Anti-siphon pressure reducing valve
quick connection, pressure resistance of 2mPa, effective pressure reduction, preventing backflow and siphoning, customized opening pressure, and protecting the safe use of equipment.
Best Valve supplier That You Can Trust
1、Over hundreds of types for selection of Valve!
2、Bio-compatible, Food Grade, Rohs, Reach, Pahs Certifications for Material. Material Selection of Chemical,Oil,Medicine,Acid,Alkaline,Ozone, Gas Resistent. Air & Liquid flow test data. Aging, lifetime, chemical resistent test data by JTSEIKO’s Lab.
3、With designers, engineers, mould workshop to provide OEM & ODM service.
4、100% Production Inspection, 0 complains with millions of valve using.
Product introduction and features
Model
picture
specification
size
DCJT084
Diamater: 28.2mm
Height: 50mm
Note:OEM & ODM services provided.
Product Solution List
number
Product Type
Advantage
03
Particles can pass through,Self-cleaning, installation easy,anti-backflow,Hundreds of plans to choose from.Often used for drainage, air refill.
04
Particles can pass through,Self-cleaning, installation easy, anti-backflow, Hundreds of plans to choose from.Often used for drainage, air refill.
07
The interface size can be freely selected and matched ( 1/8”,3/16”,1/4” ).The "in" and "out" directions can be optionally converted; Cracking Pressure Customized.
09
Cracking Pressure: 0-3kPa, Customized cracking pressure tolerance ±3kPa, high performance of vacuum sealing.
12
Quick connection, pressure resistance of 2mPa, effective pressure reduction, preventing backflow and siphoning, customized opening pressure, and protecting the safe use of equipment.
13
1、No leakage by reverse 300kPa without puncture 2、No leakage by reverse 38kPa after puncture 3、Smooth passage of instrumentssuch as sheaths and guide wires
14
1、Transmittance≤15% 2、No Decolorization 3、Cracking pressure ≤2kPa, no leakage in reverse 2kPa & 200kPa. Customized cracking pressure
18
Straight/Y/T/L shape connector;medical grade PP material, 100,000 grade clean-room production.
Customized services
Product & Mould Design
Mould Process
Quality Control
Mass Production
Why Choose Us
OEM & ODM project
Our service includes design, research & innovation, mould process, lab test, mass production and quality control etc.
Product Design
1, Professional designer for ODM work with 20 years' experience.
2, Review with customers together to meet market's request.
Mould & Product Process
1, CNC, Sodick EMD Machine, CMM of Serein to gurantee mould size.
2, Mould review with customer's engineer together to make sure details.
Labratory & Quality Control
1, Quality control by ISO9001 standards with first article inspection, patrol inspection every 2 hours, OQC, IQC, PPAP standards etc.
2, Lab test includes air/water flow, aging, chemical/UV/high & low tempreture resistent, vibration, tensile, etc.
Mass Production
1, 100% test for every product.
2, Automatic assembling and testing is widely used.
plastic materials Selection
Item
Plastic Material Specification
PC
1. Medical Using Mostly, with Bio-compatible Reports
Nylon66(PA66)
1.Tempreture durance from -40℃ to 120℃.
2.Good chemical & weather resistant.
3.Weakness:Absorb water .
ABS
1.Tempreture durance from -40℃ to 80℃.
2.Excellent dimensional stability.
3.Weakness: chemical & weather resistant.
PP
1.Tempreture durance from 0℃ to 80℃.
2.Good chemical resistant.
3.Weakness: poor weather resistant and low tempreture.
PVDF
1.Tempreture durance from -40℃ to 150℃.
2.Excellent chemical resistant.
3.Weakness: expensive.
Note: Contact our engineer to learn more about materials’ info, such as PVC, PE, PC, PMMA,POM, TPU etc.
Plant environment
Anti Siphon Pressure Reducing Valve
Anti Siphon Pressure Reducing Valve FAQ (Simplified)
- What is the core principle of the Anti Siphon Pressure Reducing Valve?
A: It reduces inlet pressure to a stable outlet pressure by dynamically adjusting flow resistance (e.g., narrowing the passage area). Excess energy (e.g., 800kPa input → 100-200kPa output) is dissipated internally (via springs, channels, etc.), maintaining pressure balance using fluid force and spring regulation.
- How does it prevent siphon/backflow?
A: It integrates two functions:
- Pressure Reduction: Regulates high inlet pressure to a safe outlet range.
- Anti-Siphon Check Valve: Features a one-way flow design with >2kPa activation pressure (per YY0585.4). If downstream pressure drops (e.g., siphon risk), the valve closes tightly to block reverse flow, preventing contamination (e.g., dirty water from plumbing back into mains).
- What are its key advantages?
A:
• Cost & Space Efficiency: Combines + into one unit.
• Hygiene Protection: Stops wastewater from re-entering clean water pipes.
• Fail-Safe Design: Normally open (ensures flow), but closes instantly if pressure reverses.
• Standards-Compliant: Meets YY0585.4 for medical-grade reliability.
- Where is it commonly used?
A:
• Plumbing systems (toilet tanks, faucets) to prevent backflow pollution.
• Medical devices (e.g., IV lines) requiring pressure control + contamination prevention.
• Irrigation networks with risk of siphon due to fluctuating pressures.